Andersen CB00011072401 Intrusion Detector-400-DH Sensor User Manual

Andersen Corporation Intrusion Detector-400-DH Sensor Users Manual

Users Manual

Parts Included / Partes Incluidas  (1)  Instruction Guide / Instruction Guide    (4)  VeriLock Face Plate / VeriLock Face Plate  (1)  VeriLock Sensor / VeriLock Sensor  (1)  Actuator  / Actuator  (2)  CR-2032 Battery / CR-2032 Battery (1)  Cylinder Magnet / Cylinder Magnet (1)  Block Magnet / Block Magnet  (2)  Cylinder Magnet Cap/ Cylinder Magnet Cap  (2)  Block Magnet Cap/ Block Magnet Cap  (2)  Screw Standoff / Screw Standoff  (1)  4-1/4" Spindle / 4-1/4" Spindle  (4)  #8 x 1-3/4" Bolt (2 white, 2 stone)        (Tribeca® Hardware Only) /    #8 x 1-3/4" Bolt (2 white, 2 stone)        (Tribeca® Hardware Only)   9139831 BA-01   Revised 02/21/16VeriLock® Security Sensor ApplicationVeriLock® Security Sensor Application ▶Read guide from beginning to end before starting installation. Read all warnings and cautions during unit installation.  Lea completamente la guía antes de comenzar la instalación. Lea y respete todas las advertencias y precauciones durante la instalación de la unidad. ▶Check with your local building code ofcial to identify and conrm compliance with local building code requirements.    Consulte los códigos locales de construcción para identicar y conrmar que se cumplan los requisitos del código de construcción.Thank you for choosing Andersen. / Gracias por elegir Andersen.“Andersen” and all other marks where denoted are trademarks of Andersen Corporation and its subsidiary. © 2016 Andersen Corporation. All rights reserved.“Andersen” y todas las demás marcas que aparezcan son marcas registradas de Andersen Corporation y su subsidiaria © 2016 Andersen Corporation. Todos los derechos reservados.for Andersen® A-Series Frenchwood Hinged Inswing & Outswing, 400 Series Frenchwood® Hinged Inswing & Outswing and Hinged Inswing & Outswing Entry Doorsfor Andersen® A-Series Frenchwood Hinged Inswing & Outswing, 400 Series Frenchwood® Hinged Inswing & Outswing and Hinged Inswing & Outswing Entry DoorsFor questions call 1-888-888-7020. For more information and/or guides visit andersenwindows.com.Please leave this guide with building owner.Si tiene alguna pregunta llame al 1-888-888-7020.  Para obtener más información y/o guías, visite andersenwindows.com.Deje esta guía con el dueño de la construcción.VeriLock® Face Plate VeriLock® Face Plate VeriLock® SensorVeriLock® SensorScrew StandoffScrew StandoffBlock MagnetBlock MagnetDepending on individual installation requirements, some parts may not be used.Depending on individual installation requirements, some parts may not be used.Cylinder MagnetCylinder MagnetCylinderMagnet CapCylinder Magnet Cap CR-2032 BatteryCR-2032 BatteryActuatorActuatorBlock Magnet CapBlock Magnet Cap Additional Parts Required for Entry Doors Only (Ordered Seperately)Additional Parts Required for Entry Doors Only (Ordered Seperately)(1)  Extended Lock Actuator /   Extended Accionador del cerrojo #8 x 1-3/4" Bolt(Tribeca Hardware Only)#8 x 1-3/4" Bolt(Tribeca Hardware Only)4-1/4" Spindle4-1/4" SpindleTools Needed / Herramientas Necesarias ∙Safety Glasses / Lentes de seguridad ∙Phillips Screwdriver / Destornillador Phillips ∙1/8" Hex Key / Hex Key de 1/8" ∙Drill/Driver / Taladro/destornillador ∙5/16" Drill Bit / Broca para taladro de 5/16" ∙Tape Measure / Tape Measure ∙Drop Cloth / Drop Cloth
29139831Use caution when working at elevated heights and around unit openings. Follow manufacturers’ instructions for ladders and/or scaffolding. Failure to do so may result in injury or death.Sea cauteloso al trabajar en lugares elevados y cerca de las aberturas de la unidad. Siga las instrucciones del fabricante para el uso de escaleras y/o andamios. Si no lo hiciera, podrían producirse lesiones o la muerte.Follow manufacturers’ instructions for hand or power tools. Always wear safety glasses. Failure to do so may result in injury and/or product damage.Siga las instrucciones del fabricante para el uso de herramientas eléctricas o manuales. Utilice siempre gafas de seguridad. Si no lo hiciera, podrían producirse lesiones y/o daños al producto.Batteries carry the risk of re, explosion and burns. Do not recharge, disassemble, heat above 212 degrees F (100 degrees C) or incinerate. Dispose of used batteries promptly and properly. Keep away from children.Les piles représentent un risque d’incendie, d’explosion et de brûlures. Ne pas recharger, démonter, chauffer à une température excédant 100degrés C (212degrésF) ou incinérer. Éliminer les piles rapidement et de manière appropriée. Garder à l’écart des enfants.Magnets are small parts and, if swallowed, could pose a choking hazard to young children.  Los imanes son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asxia para niños pequeños.Magnetic eld can be harmful to implanted medical device wearers. Keep magnets away from devices.Magnetic eld can be harmful to implanted medical device wearers. Keep magnets away from devices.Batteries are small parts and, if swallowed, could pose a choking hazard to young children.  Las baterías son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asxia para niños pequeños.
391398311InteriorLay a drop cloth down to prevent losing parts. Unlock and open active door panel. Loosen set screw on exterior handle using 1/8" hex key. Remove handles and set aside for reuse.Lay a drop cloth down to prevent losing parts. Unlock and open active door panel. Loosen set screw on exterior handle using 1/8" hex key. Remove handles and set aside for reuse.3InteriorLoosen cylinder mounting bolts until exterior components can be removed. Set exterior components aside for reuse.  Loosen cylinder mounting bolts until exterior components can be removed. Set exterior components aside for reuse.  Dummy CylinderFalso cilindroCylinder Mounting Bolts(do not fully remove)Pernos de montaje del cilindro(do not fully remove)Exterior Active Escutcheon Escudete con apertura exteriorGasketJuntaLock MechanismMecanismo del cerrojoSupport exterior components when loosening cylinder mounting bolts.Support exterior components when loosening cylinder mounting bolts.Remove escutcheon bolts and interior active escutcheon. Set aside for reuse.  Remove escutcheon bolts and interior active escutcheon. Set aside for reuse.  Exterior HandleManija exteriorInterior HandleManija interiorSet ScrewTornillo de jación1/8" Hex KeyHex Key de 1/8" BushingCasquilloBushingCasquilloSpindleHusillo2InteriorEscutcheon Bolt Perno de escudete Interior Active Escutcheon Escudete con apertura interiorFor Entry Doors only, remove cylinder mounting bolts, limiting plate and lock actuator. Replace existing lock actuator with extended lock actuator. Reapply parts as shown, do not fully tighten bolts.For Entry Doors only, remove cylinder mounting bolts, limiting plate and lock actuator. Replace existing lock actuator with extended lock actuator and reapply parts as shown, do not fully tighten bolts.Entry Doors Only /Entry Doors OnlyLock ActuatorLock ActuatorCylinder Mounting BoltsPernos de montaje del cilindroLimiting PlatePlaca limitadoraExisting Lock ActuatorExisting Lock ActuatorExtended Lock ActuatorExtended Lock Actuator
491398314InteriorApply screw standoffs to mounting studs on back side of exterior escutcheon as shown.Apply screw standoffs to mounting studs on back side of exterior escutcheon as shown.Re-apply exterior components and tighten cylinder mounting bolts.Re-apply exterior components and tighten cylinder mounting bolts.Screw StandoffScrew StandoffScrew StandoffScrew StandoffExterior Active Escutcheon Escudete con apertura exteriorVerify gasket is seated properly.Verify gasket is seated properly.Cylinder Mounting BoltsPernos de montaje del cilindroMounting StudMounting StudMounting StudMounting StudDummy CylinderFalso cilindroExterior Active Escutcheon Escudete con apertura exteriorRemovable Mounting StudRemovable Mounting StudScrew StandoffScrew StandoffScrew StandoffScrew StandoffRemovable Mounting StudRemovable Mounting StudFor Tribeca hardware only, apply removable mounting studs as shown, then apply screw standoffs to mounting studs on back side of exterior escutcheon as shown.For Tribeca hardware only, apply removable mounting studs as shown, then apply screw standoffs to mounting studs on back side of exterior escutcheon as shown.Verify gasket is seated properly.Verify gasket is seated properly.Exterior Active Escutcheon Escudete con apertura exterior6InteriorSelect preferred color VeriLock face plate. Press sensor into back side of face plate and install batteries with (+) facing out as shown. Indicator light will illuminate for one (1) second when batteries are installed correctly.Select preferred color VeriLock face plate. Press sensor into back side of face plate and install batteries with (+) facing out as shown. Indicator light will illuminate for one second when batteries are installed correctly.(back views)(back views)VeriLock® AssemblyVeriLock® AssemblyVeriLock Face PlateVeriLock Face PlateVeriLock Sensor VeriLock Sensor CR-2032 BatteriesCR-2032 Batteries5Interior(front view)(front view)Indicator LightIndicator LightTribeca® Hardware OnlyTribeca® Hardware Only
591398317Interior8InteriorVerify panel surface is clean and dry. Position VeriLock assembly on the panel over the lock actuator as shown.  The indicator will illuminate for one (1) second when the sensor is applied to the panel as the anti-tamper switch is depressed.Verify panel surface is clean and dry. Position assembly on the panel over the lock actuator as shown.  The indicator will illuminate for one (1) second when the sensor is applied to the panel as the anti-tamper switch is depressed.Rotate VeriLock assembly to the correct orientation (tab side must point toward the latch side of panel). Insert actuator into top hole of VeriLock assembly from back side as shown. Rotate VeriLock assembly to the correct orientation. (tab side must point toward the latch side of panel).Tab side as viewed from back.Tab side as viewed from back.Top HoleTop HoleVeriLock AssemblyVeriLock AssemblyLock ActuatorAccionador del cerrojoActuatorAccionadorActuator(in top hole only)Actuator(in top hole only)Alignment Tabs(will fit in only one orientation)Alignment Tabs(will fit in only one orientation)(Verify arrows align on the tab side as shown)(Verify arrows are aligned as shown on the tab side)VeriLock® Assembly(tab must point toward latch side of panel)VeriLock® Assmbly(tab must point toward latch side of panel)VeriLock assembly can be rotated for use on either left handed (LH) or right handed (RH) panels.VeriLock assembly can be rotated for use on either left handed (LH) or right handed (RH) panels.LatchLatchTabTabVeriLock® Assembly(back view)VeriLock® Assmbly(back view)VeriLock Sensor(anti-tamper switch)VeriLock Sensor(anti-tamper switch)Sensor contains an anti-tamper switch. Do not apply sensor over wet nish or rough/dirty surface. Improper switch function may result.Sensor contains an anti-tamper switch. Do not apply sensor over wet nish or rough/dirty surface. Improper switch function may result.Indicator LightIndicator Light
69139831Handles must point toward the glass with set screw on the bottom.Las manijas deben apuntar hacia el vidrio con el tornillo de jación en la parte inferior.Slide handles and bushings together tightly.  Insert set screw in exterior handle and tighten using hex key. Finish tightening escutcheon bolts.Slide handles and bushings together tightly.  Insert set screw in exterior handle and tighten using hex key. Finish tightening escutcheon bolts.Position interior escutcheon on panel as shown and fasten bolts (do not fully tighten until handles have been installed). Position interior escutcheon on panel as shown and fasten bolts (do not fully tighten until handles have been installed). 9InteriorLoosen set screw on handle and remove spindle.  Replace existing spindle with 4-1/4"spindle and tighten set screw. Set screw must enter v-slot in spindle when securing the handle. Loosen set screw on handle and remove spindle.  Replace existing spindle with extended spindle and tighten set screw. Set screw must enter v-slot in spindle when securing the handle. Escutcheon Bolt Perno de escudete Interior Active Escutcheon Escudete con apertura interior10InteriorSpindleHusilloExterior HandleManija exteriorInterior HandleManija interiorSet ScrewTornillo de jaciónHex KeyHex Key BushingCasquilloBushingCasquilloLine up v-slot with set screwAlinee la ranura en forma de V con el tornillo de fijaciónSpindle (V-Slot)Husillo (ranura en forma de V)Set ScrewTornillo de jación11InteriorBottom View/Vista inferior  SpindleHusilloTribeca® Hardware OnlyTribeca® Hardware OnlyReplace existing bolts with #8 x 1-3/4" bolts.Replace existing bolts with #8 x 1-3/4" bolts.#8 x 1-3/4" Bolt#8 x 1-3/4" BoltHex KeyHex Key4-1/4" Spindle4-1/4" SpindleExisting SpindleExisting Spindle
79139831 Magnet Application/ Magnet Application ▶For DOUBLE operating, OUTSWING doors, go to Step 12a.     For DOUBLE operating, OUTSWING doors, go to Step 12a. ▶For DOUBLE operating, INSWING doors, go to Step 12b.     For DOUBLE operating, INSWING doors, go to Step 12b. ▶For SINGLE operating, OUTSWING doors, go to Step 12c.     For SINGLE operating, OUTSWING doors, go to Step 12c. ▶For SINGLE operating, INSWING doors, go to Step 12d.     For SINGLE operating, INSWING  doors,           go to Step 12d.Magnets are small parts and, if swallowed, could pose a choking hazard to young children.  Los imanes son partes pequeñas que, en caso de ingesta, pueden representar un riesgo de asxia para niños pequeños.Determine door your conguration and proceed to appropriate section for magnet installation.Determine door your conguration and proceed to appropriate section for magnet installation.Selection of the correct door conguration is critial for magnet application. Wrong conguration selection will result in improper magent application and product damage.Selection of the correct door conguration is critial for magnet application. Wrong conguration selection will result in improper magent application and product damage.OrOrOrOrOrOrAs viewed from the exterior.As viewed from the exterior.As viewed from the exterior.As viewed from the exterior.As viewed from the exterior.As viewed from the exterior.As viewed from the exterior.As viewed from the exterior.12Stationary PanelStationary PanelStationary PanelsStationary Panels
Order Designation DescriptionViewed from the exterior. Viewed from the exterior.Order Designation DescriptionViewed from the exterior.6068 S  A  LDoor RoughOpeningStationaryPanelActivePanelLeft Hinged6068 A  S  RDoor RoughOpeningActive PanelStationaryPanelRightHingedDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHingedDoor RoughOpeningStationaryPanelActivePanelStationaryPanelRightHinged6068 A  P  L  R 9068 S  A  S  RFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWH Frenchwood Hinged Patio Doors - InswingFWH Frenchwood Hinged Patio Doors - OutswingDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHinged6068 A  P  L  RFWOFrenchwood®Hinged OutswingPatio DoorLeft Hinged(hinges on left) Active Panel(operating panelused most often)Passive Panel(operating panel with attached astragal)Stationary (non-operating panel)Right Hinged(hinges on right) 89139831Install magnet on your DOUBLE operating, OUTSWING, door as shown.Install magnet on your DOUBLE operating, OUTSWING, door as shown.As viewed from the exterior.As viewed from the exterior.Cylinder MagnetCylinder MagnetPress cylinder magnet rmly into preferred color cylinder magnet cap.Press cylinder magnet rmly into preferred color cylinder magnet cap.Cylinder Magnet CapCylinder Magnet CapInterior ViewInterior ViewFor DOUBLE Operating, OUTSWING Doors OnlyFor DOUBLE Operating, OUTSWING  Doors Only12aClose doors and lightly mark magnet location across from bottom arrow on VeriLock face plate, as shown.Close doors and lightly mark magnet location across from bottom arrow on VeriLock face plate, as shown.Open active panel and drill 5/16" hole at marked location in center of astragal side, as shown. Open active door and drill 5/16" hole at marked location in center of side surface, as shown.Insert cylinder magnet with cap into drilled hole.Insert cylinder magnet with cap into drilled hole.5/16" Drill Bit5/16" Drill BitPassive PanelPassive PanelAstragalAstragalAstragalAstragalInterior ViewInterior ViewActive PanelActive PanelCenter of astragal side.Center of astragal side.
9913983112b For DOUBLE Operating, INSWING Doors OnlyFor DOUBLE Operating, INSWING Doors OnlyOrder Designation DescriptionViewed from the exterior. Viewed from the exterior.Order Designation DescriptionViewed from the exterior.6068 S  A  LDoor RoughOpeningStationaryPanelActivePanelLeft Hinged6068 A  S  RDoor RoughOpeningActive PanelStationaryPanelRightHingedDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHingedDoor RoughOpeningStationaryPanelActivePanelStationaryPanelRightHinged6068 A  P  L  R 9068 S  A  S  RFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWH Frenchwood Hinged Patio Doors - InswingFWH Frenchwood Hinged Patio Doors - OutswingDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHinged6068 A  P  L  RFWOFrenchwood®Hinged OutswingPatio DoorLeft Hinged(hinges on left) Active Panel(operating panelused most often)Passive Panel(operating panel with attached astragal)Stationary (non-operating panel)Right Hinged(hinges on right) Position block magnet with cap to front surface of passive panel, ush to edge, and centered across from bottom arrow on VeriLock face plate.Position block magnet with cap to front surface of passive panel, ush to edge, and centered across from bottom arrow on VeriLock face plate.Remove adhesive liner from one side of block magnet and press rmly into preferred color block magnet cap.Remove adhesive liner from one side of block magnet and press rmly into preferred color block magnet cap.Block MagnetBlock MagnetBlock Magnet CapBlock Magnet CapInstall magnet on your DOUBLE operating, INSWING, door as shown.Install magnet on your DOUBLE operating, INSWING, door as shown. As viewed from the exterior.As viewed from the exterior.Interior ViewInterior ViewBottom ArrowBottom ArrowActive PanelActive PanelPassive PanelPassive PanelEdge of Passive PanelEdge of Passive Panel Remove second adhesive liner from block magnet with cap.Remove second adhesive liner from block magnet with cap.
10913983112c For SINGLE Operating, OUTSWING Doors OnlyFor SINGLE Operating, OUTSWING Doors OnlyInstall magnet on your SINGLE operating, OUTSWING, door as shown. Install magnet on your SINGLE operating, OUTSWING, door as shown. Order Designation DescriptionViewed from the exterior. Viewed from the exterior.Order Designation DescriptionViewed from the exterior.6068 S  A  LDoor RoughOpeningStationaryPanelActivePanelLeft Hinged6068 A  S  RDoor RoughOpeningActive PanelStationaryPanelRightHingedDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHingedDoor RoughOpeningStationaryPanelActivePanelStationaryPanelRightHinged6068 A  P  L  R 9068 S  A  S  RFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWH Frenchwood Hinged Patio Doors - InswingFWH Frenchwood Hinged Patio Doors - OutswingDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHinged6068 A  P  L  RFWOFrenchwood®Hinged OutswingPatio DoorLeft Hinged(hinges on left) Active Panel(operating panelused most often)Passive Panel(operating panel with attached astragal)Stationary (non-operating panel)Right Hinged(hinges on right) Lightly mark magnet location on panel stop across from bottom arrow on VeriLock face plate, as shown.Lightly mark magnet location on panel stop across from bottom arrow on VeriLock face plate, as shown.Open door and drill 5/16" hole, 1" deep, 1/4" from panel stop edge.Open door and drill 5/16" hole, 1" deep, 1/4" from panel stop edge.Insert cylinder magnet with cap into drilled hole.Insert cylinder magnet with cap into drilled hole.As viewed from the exterior.As viewed from the exterior.Interior ViewInterior ViewInterior ViewInterior ViewCylinder MagnetCylinder MagnetPress cylinder magnet rmly into preferred color cylinder magnet cap.Press cylinder magnet rmly into preferred color cylinder magnet cap.Cylinder Magnet CapCylinder Magnet CapBottom ArrowBottom ArrowPanel StopPanel Stop1/4"5/16" Drill Bit5/16" Drill Bit
11913983112d For SINGLE Operating, INSWING Doors OnlyFor SINGLE Operating, INSWING Doors OnlyInstall magnet on your SINGLE operating, INSWING, door as shown. Install magnet on your SINGLE operating, INSWING, door as shown. Order Designation DescriptionViewed from the exterior. Viewed from the exterior.Order Designation DescriptionViewed from the exterior.6068 S  A  LDoor RoughOpeningStationaryPanelActivePanelLeft Hinged6068 A  S  RDoor RoughOpeningActive PanelStationaryPanelRightHingedDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHingedDoor RoughOpeningStationaryPanelActivePanelStationaryPanelRightHinged6068 A  P  L  R 9068 S  A  S  RFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWH Frenchwood Hinged Patio Doors - InswingFWH Frenchwood Hinged Patio Doors - OutswingDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHinged6068 A  P  L  RFWOFrenchwood®Hinged OutswingPatio DoorLeft Hinged(hinges on left) Active Panel(operating panelused most often)Passive Panel(operating panel with attached astragal)Stationary (non-operating panel)Right Hinged(hinges on right) Order Designation DescriptionViewed from the exterior. Viewed from the exterior.Order Designation DescriptionViewed from the exterior.6068 S  A  LDoor RoughOpeningStationaryPanelActivePanelLeft Hinged6068 A  S  RDoor RoughOpeningActive PanelStationaryPanelRightHingedDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHingedDoor RoughOpeningStationaryPanelActivePanelStationaryPanelRightHinged6068 A  P  L  R 9068 S  A  S  RFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWHFrenchwood®Hinged InswingPatio DoorFWH Frenchwood Hinged Patio Doors - InswingFWH Frenchwood Hinged Patio Doors - OutswingDoor RoughOpeningActive Panel(panel usedmost often)PassivePanelLeftHingedRightHinged6068 A  P  L  RFWOFrenchwood®Hinged OutswingPatio DoorLeft Hinged(hinges on left) Active Panel(operating panelused most often)Passive Panel(operating panel with attached astragal)Stationary (non-operating panel)Right Hinged(hinges on right) Open door and mark magnet location on jamb (even with bottom strike plate screw and centered in the area between the strike plate and jamb edge).Open door and mark magnet location on jamb (even with bottom strike plate screw and centered in the area between the strike plate and jamb edge).As viewed from the exterior.As viewed from the exterior.Cylinder MagnetCylinder MagnetInterior ViewInterior ViewInterior ViewInterior View5/16" Drill Bit5/16" Drill BitDrill 5/16" hole, 1" deep, at marked location.Drill 5/16" hole, 1" deep, at marked location.Insert cylinder magnet with cap into drilled hole.Insert cylinder magnet with cap into drilled hole.Strike PlateStrike PlateEdge of jamb.                            Edge of jamb. JambJambPress cylinder magnet rmly into preferred color cylinder magnet cap.Press cylinder magnet rmly into preferred color cylinder magnet cap.Cylinder Magnet CapCylinder Magnet Cap
1291398311.   Close door without locking. Indicator light will illuminate for one (1) second.2.   Engage all upper, middle and lower hooks and lock door with dead bolt. Indicator light will illuminate for one (1) second. Verify door is locked. 3.   Unlock door with dead bolt. Indicator light will illuminate for one (1) second.4.   Open door.  Indicator light will illuminate for one (1) second.1.   Close door without locking. Indicator light will illuminate for one (1) second.2.   Engage all upper, middle and lower hooks and lock door with dead bolt. Indicator light will illuminate for one (1) second. Verify door is locked. 3.   Unlock door with dead bolt. Indicator light will illuminate for one (1) second.4.   Open door.  Indicator light will illuminate for one (1) second.Verify VeriLock® sensor function. If indicator light does not respond as described, verify sensor application and magnet placement.Verify VeriLock® sensor function. If indicator light does not respond as described, verify sensor application and magnet placement.Refer to monitoring system of your choice for sensor enrollment. / Refer to monitoring system of your choice for sensor enrollment.For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide.For maintenance information, please visit http://www.andersenwindows.com/verilock and consult with the VeriLock user guide. ▶Procedure is complete. Procedure is complete. Verify VeriLock Sensor Function / Verify VeriLock Sensor Function13Interior Thumb Turn LatchThumb Turn LatchUnlockedUnlocked LockedLockedIndicator LightIndicator Light
139139831Federal Communications Commission (FCC) Part 15 Statement This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be received, including interference that may cause undesired operation. Industry Canada (IC) RSS StatementThis device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.  L'exploitation est autorisée aux deux conditions suivantes: (1) I'appareil ne doit pas produire de brouillage; (2) I'utilisateur de I'appareil doit accepter tout brouillage radioélectrique subi, méme si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by Andersen may void the user's authority to operate the equipment.  Federal Communications Commission (FCC) Part 15 Statement This device complies with FCC Rules Part 15. Operation is subject to the following two conditions: (1) This device may not cause harmful interference. (2) This device must accept any interference that may be received, including interference that may cause undesired operation. Industry Canada (IC) RSS StatementThis device complies with Industry Canada license-exempt RSS standard(s). Operation is subject to the following two conditions: (1) This device may not cause interference, and (2) This device must accept any interference, including interference that may cause undesired operation of the device. Le présent appareil est conforme aux CNR d'Industrie Canada applicables aux appareils radio exempts de licence.  L'exploitation est autorisée aux deux conditions suivantes: (1) I'appareil ne doit pas produire de brouillage; (2) I'utilisateur de I'appareil doit accepter tout brouillage radioélectrique subi, méme si le brouillage est susceptible d'en compromettre le fonctionnement. Changes or modifications not expressly approved by Andersen may void the user's authority to operate the equipment.   Regulatory Statements / Regulatory Statements

Navigation menu