Deltanode Solutions DDH850 43dBm High Power Remote User Manual Fiber Distributed Antenna System DAS
Deltanode Solutions AB 43dBm High Power Remote Fiber Distributed Antenna System DAS
Contents
- 1. User Manual_Part 1
- 2. User Manual_Part 2
User Manual_Part 1



























![FiberDistributedAntennaSystem(FiberDAS)17Figure 14 DETECTORLASERDRIVERETHERNETMODEMOPTO OUTDETECTORMONITORTX-LVLDL IN 1DL IN 2TP DLSTEP ATTAttenuator 1Downlink 1Attenuator 1Downlink 2Attenuator 2Downlink 1Attenuator 2Downlink 2STEP ATTSTEP ATTSTEP ATTFOI Downlink Block DiagramTheRFdrivelevelsaremeasuredandaccessibleinthewebinterface.TPDLisatestpointmeasurementportforthedownlinkpath.TheRFlevelatTPDLwillbethesameastheinputtotheDLportsminustheGUIattenuatorsettings.TPDL=“DLIN1"minus“Att.1Downlink1"minus“Att.2Downlink1".TPDL=“DLIN2"minus“Att.1Downlink2"minus“Att.2Downlink2".Example:InputintoDLis‐25dBmwiththeGUIsettingfor“Att.1Downlink1"of10andaGUIsettingfor“Att2Downlink1"of0.Thetestpointmeasurementwillbe:‐25dB(input)minus10dB(attenuator#1)minus0dB(attenuator#2)=‐35dBm.Figure15isablockdiagramshowingtheuplinkpathintheFOIandhowthetestportisconnected.Therearetwocommonattenuators,andtwouplinkattenuatorsthatcanbesetintheuplinkpath.Figure 15 FOI Uplink Block DiagramDETECTORDETECTORCURRENTSENSORETHERNETMODEMOPTO INRX-LVLUL OUT 2UL OUT 1TP ULAttenuator Common 1PHOTODETECTORAttenuator Common 2Attenuator Uplink 1Attenuator Uplink 2STEP ATT STEP ATTSTEP ATTSTEP ATTRX POWER 1RX POWER 2TheULtestportontheFOIistappedbeforetheindividualuplinkpathattenuators.TheoutputlevelofTPULwillbe:TP/UL[dB]=“Att.Uplink1"setting‐20dBTP/UL[dB]=“Att.Uplink2"setting‐20dBExample:IftheFOIGUIsettingfor“Att.Uplink1"is0,thetestportuplinkpath1signalswillbe20dBlowerthantheuplinksignalonthe“ULOut1"port.Example:IftheFOIGUIsettingfor“Att.Uplink2"is20,thetestportuplinkpath2signalswillbeequaltotheuplinksignalson“ULOut2"port.](https://usermanual.wiki/Deltanode-Solutions/DDH850.User-Manual-Part-1/User-Guide-3666757-Page-28.png)
























![Installationguidelines42Tools and Material RequirementsFiber OpticsAllfiberopticcables,includingpatchcords,mustbeSINGLEMODE.Multi‐modefiberisnotsupported.BirdequipmentisdesignedtobeusedwithonlySC/APCfiberconnectors.AllconnectionpointsinthefibermusteitherbefusionsplicedorequippedwithAPCconnectors.UPCconnectorsanywhereinthefiberpathwillcausedegradationintheperformanceoftheequipment.APCconnectorscanbeidentifiedbytheirgreenjacket.Tota lopticallossmustbe<15dBo.Opticalreturnloss‐60dBorgreater.Fiberpanelinserts/couplingsmustbeAPC.ToolsFiberOpticcleanerforSC/APCconnectorsT8TorxbitforcardcagemodulesAppropriatebitforrackscrewsSpectrumanalyzerwithRFpowermeterAppropriatejumpercablestoconnectspectrumanalyzertoBirdequipmentOTDROpticalpowermeterOpticalvisualfaultfinderFibersplicerSMAtorquewrenchcalibrateto0.9N‐mESDStrap‐(ElectrostaticDischarge):TheBIU,FOIandPowerSuppliescontainhighlysensitivecomponentsthatcanbedestroyedbystatic.NEVERopencards,BGW,CGW,repeatersorremotes!Miscellaneous MaterialACpowercord(s)ifusingtheDPU‐301powersupply[ACtoDCpowersupply]18AWGpowerwireifusingtheDPU‐302powersupply[DCtoDCpowersupply]FerritebeadfilterfortheDCsupplycabletotheDPU‐302.TheferritebeadfiltermustbeinstalledclosetotheDPU‐302.Followmanufacturerrecommendationsforproperinstallationoftheferritebeadfilter.](https://usermanual.wiki/Deltanode-Solutions/DDH850.User-Manual-Part-1/User-Guide-3666757-Page-53.png)





![Installationguidelines48ICUTheICUisdesignedtobeinstalledina19"rack.TheICUistypicallyinstalleddirectlyaboveorbelowtheMasterUnitchassis.ConsiderpostinstallationchangesandtestingwhenselectingaslottoinstalltheICU.Figure 35 ICUTheICUhasQMAconnectors.QMAcablekit‐BirdpartnumberDCC320isavailableforusewiththeICU.Thekitcontains32QMAtoQMAcables(seeTable60)thatcanbeusedtopatchbetweentheBIUtotheICU,BIUtotheFOIorICUtoFOI.Table 60 QMA Cable KitTheICUisconfiguredwithtwoidenticalpaths‐uplinkanddownlink.Thetypicalconfiguration[DIU301(88MHzto2700MHz)]isfour1:8splitters/combiners(twoforULandtwoforDL).NotethatthetheoreticallossforeachDIU301is35dBm.FOITheFOIismountedintheMasterUnitchassis.TheFOIusesoneslotintheMasterUnit.TheRFconnectionsareQMA.ThefiberconnectionsareSC/APC.TheFOIcanbeorderedwithanoptionalDCC330jumperkit.ThekitcontainstwoSC/APCjumpersthatare5meters(16.4feet)inlength.Figure 36 FOI ConnectionsOPTO IN/OUTforRemote UnitsUplinkDownlinkLength Quantity250mm(9.8”) 13350mm(13.8”) 13500mm(19.7”) 6](https://usermanual.wiki/Deltanode-Solutions/DDH850.User-Manual-Part-1/User-Guide-3666757-Page-59.png)