a.In standby mode, using a pen to press LEARN button once will sound beep, press again will sound other one, press the button select sound for you want, then keep press LEARN button 2 seconds will hear a beep tone then release the button, the unit now ready to receive learn code signal from transmitter.b.Trigger wireless garage door open detector sensor (pull up and put down detection rob will trigger it ), you will hear a long beep tone confirming that the progamming of learn code was done successfully (When programming LEARN  code was unsuccessful, you will hear four short beep tones). Please program again.Learn ID code to T016S,T015S auto dialer main unit:a. Open terminal compartment of main unit. ( Fig.4)b. Press and hold LEARN button 2 seconds you will hear one beep tone then un-pressed the button, the unit now ready to receive learn code signal from transmitter.c. Trigger wireless garage door open detector sensor (pull up and put down detection rob will trigger it ).d. You will hear a long beep tone confirming that the programming of     learn code was done successfully (When programming LEARN  code was unsuccessful, you will hear four short beep tones). Please program again.Learn ID code to T018S auto dialer main unit:(Fig.5)a. Enter the pass number followed by[PROG]button three times.b. The " LEARN " icon will flash on the LCD.c. Press[ARM/DISARM]to confirm, the system will turn into learning ID code setup and zone 1 icon flash.d. Press the[*/UP]and[#/DOWN]buttons to select you want setup zone, when LCD display “NO ID CODE” is meaning the zone is disengaged, you can learn new sensor id code for this zone; when LCD display “FULL” is meaning the zone had ID code,you    can select other zone or press[DEL./PAUSE]button to delete ( Fig. 4 )( Fig.5)2    original id code then relearn new id code for this zone. e. Press[ARM/DISARM]to confirm.f.  Trigger wireless garage door open detector sensor (pull up and put down detection rob will trigger it ).(Fig.5)g. you will hear a long beep tone confirm learn code successfully and LCD will display “FULL” for  zone 1 ~ zone 8 or  “1 ID CODE IN” for zone 9.h. press[PROG]button seven times to exit the setup mode.Learn ID code to 526L wireless outdoor siren with flash light:a. Open battery compartment cover. ( Fig.6)b. use a pen to press and hold LEARN button for 2 seconds, a beep tone will sound , then release the button, the unit now ready to receive LEARN ID code signal from transmitter.c. Trigger wireless garage door open detector sensor (pull up and put down detection rob will trigger it )d. you will hear a long beep tone confirming that the programming    of learn code was done successfully (When programming LEARN  code was unsuccessful, you will hear four short beep tones). Please program again.4. TO TEST TRANSMITION RANGE    After select a location, you should test the sensor transmitting range before mount it permanently, turn power switch to ON of 625RX main unit or turn the CHIME switch to ON of T015S main unit or press HOME button of T018S, after 60 seconds,  then Trigger wireless garage door open detector sensor (pull up and put down detection rob will trigger it ), you will hear the main unit sounds “DING DONG” chime or alert sound if signal is received successfully, if not , change location is required.5.Installation for up/down type garage door:a.Before you install the sensor onto the garage door, make sure the garage door is closed, the sensor assembly should be mounted on one of the vertical supports of your garage door near the bottom. When the door is closed, the detection rod should be retracted. When the door is open, the detection rod will be extended.(fig.7)( Fig.6)3Size:90X175mmp/n:610-62501-000Rwhite paper print black wordsFEATURES•  Detect garage door open out put wireless trigger signal•  Garage door sensor 3V lithium battery (CR2032) operation (included)•  IP44 Water and weather resistant •  External trigger input terminal compatible wired magnetic sensor    for normal door•  Battery low indicator LED •  Wireless RF transmission distance about 30~40 meters (open space)DESCRIPTION OF COMPONENTS1. Built-in detect sensor rod2. Built-in detect sensor rod lock3. External sensor terminal4. Battery cover5. Built-in sensor/external     sensor select switchINSTALLATION1.Remove the screw of garage door sensor battery cover, and open the battery door.(Fig.1) 2.install a 3V lithium battery (CR2032 or equate type) for garage   door sensor,  compartment make sure install with correct  polarity. (Fig.2)3. LEARN ID CODE TO MAIN UNIT    The wireless garage door open detector sensor compatible model: 625RX, T015S, T016S, T018S, 526L, must learn code to main unit then use, the learning code can only be operated during disarm mode. Follow these steps:Learn ID code to 625RX  wireless alert receiver unit:( Fig.3) LOCK UNLOCK25134(Fig.2)(Fig.1)LEARN1( Fig.3)b.You can mount the sensor onto your garage door with double-sided foam tape if the surface of your garage door is smooth and clean enough to provide a good adhesive surface, such surface can usually be found on a metal garage door. Please ensure the surface is smooth and clean. the bottom of the sensor should be 15mm above the ground.(fig.8) c.For wooden garage doors, it is recommended to mount the sensor with screws onto the garage door with screws provided. (fig.9)Note:    When the garage door is opening/closing, make sure the sensor does not interfere with the safety reversing sensor or safety beam sensor supplied with your existing garage door opener.6.Installation for external magnetic sensor :a.Remove the screw from battery compartment cover.b.Connect the external magnetic sensor (included) to terminal.(Fig.10)c.Turn sensor select switch to EXT.(external)d.Replace the battery cover and screw.    e.Pull up the detection rob to top and turn lock switch to LOCK.(fig.11)     f.Choose a suitable location, use double-sided foam tape or screws to mount the unit.   g.Mount the magnetic wired piece to the door frame and another single piece to the door by using the double-side tapes (included) (Fig.9)LOCKLOCK UNLOCK(Fig.8)LOCKLOCK UNLOCK15mm(Fig.10)(Fig.11)LOCKLOCK UNLOCK LOCKLOCK UNLOCK4(Fig.7)LOCKLOCK UNLOCKDoor closedLOCKLOCK UNLOCKDoor open  and aligned the 2 sensor pieces to be flushed and “   ” facing “   ”  at no more than 15mm. (fig.12.13.14) h.If you connect more than one sensor to unit,connect them in series as shown below.(Fig.15)i.Connect the sensor switch on door to the main terminal post using the wire you just cut. (There is no polarity need to be taken care of, any terminal will be fine, as long as the wires from a loop) OPERATIONAfter  60  seconds  installed  3V  battery,  the  unit  will  into  standby mode. Once the door/window opened will output wireless radio signal and LED flash.  BATTERY LOW INDICATOR     When garage door sensor battery goes low, sensor unit battery low led will flash once every second .FCC COMPLIANCE STATEMENT     This equipment has been tested and found to comply with the limits for a Class B digital device,  pursuant  to  Part  15  of  the  FCC  Rules. These  limits  are  designed  to  provide reasonable  protection  against harmful  interference  in  a  residential  installation.  This equipment generates, uses, and can radiate radio frequency energy and, if notLOCKLOCK UNLOCK(Fig.14)(Fig.15)5123Tape610-62501-000Rgarage doorLOCKLOCK UNLOCKabout 600mmgarage doorLOCKLOCK UNLOCKabout 600mm(Fig.12) (Fig.13)OWNER'S MANUALGarage Open AlertMODEL:625TLOCKLOCK UNLOCKinstalled and  used  in  accordance  with  the  instrucitons, may  cause harmful  interference  to  radio communications.  However,  there  is  no gurantee  that  interference  will  not  occur  in  a particular installation.      If this equipment does cuase harmful interference to radio or television reception, which can be determined by turning the equipment of f and on, the user is envouraged to try to  correct the interference by one or more the of the following measures: -  Reorient or relocate the receiving antenna.-  Increase the separation between the equipment and the receiver.-  Connect  the  equipment  into  an  outlet  on  a  circuit  different  from that  to  which  the  receiver is connected. -  Consult the dealer or an experienced technician for help.     This device complies with Part 15 of the FCC Rules and with RSS-210 of Industry  Canada. Operation is subject to the following two conditions:1)  This device may not cause harmful interference, and2)  This device must accept any interference received, including interference that may cause undesired operation. WARNING: Changes or modifications not expressly approved by Lelux could void the user’s authority to operate the equipment.      6

Navigation menu