Megaphoton H1-400COB-GAA ELECTRONIC BALLAST FOR HID LAMP User Manual

Megaphoton Inc. ELECTRONIC BALLAST FOR HID LAMP Users Manual

user manual

Electronic Ballast for  400W/600W/1000W Metal Halide or High Pressure Sodium LampsUSER MANUALGene ra tor rea dyRuns MH or HPS la mpsHigh ef fic ien c y electro nic  balla stNo a co ustic r ea sona nc eLower ha rmonic  distrotionHigh ou tput a nd improve d spectr umDriver ef fic ien c y a t full power: 95-96%Light-we ight a nd high ener gy-effic ien t.Product Advantage1.IntroductionThank you for purchasing Efinity Electronic Ballast. Please review the following instructions to ensure you receive the best  performance. Each ballast uses a high temperature,resin-sealed component board for completely silent operation. Each unit is burned-in at the factory for approximately twelve hours to ensure maximum reliability.E-Ballasts use a micro-processor similar to your home computer. This micro-processor allows the E-Ballast to run halide or sodium lamps. It is programmed for a "soft-start" and does not require an initial surge of power to light the lamp. This increase the lamp life and allows the end user to start multiple ballasts  ballasts at the same time without tripping breakers. To ensure safe operation, this Programmed for a "soft-start" and does not require an initial surge of power to light or missing lamp.In case of auto-shutoff, please disconnect from the power supply, remove the faulty lamp or check for wiring problems,wait for some minutes then restart your ballast.Power cord with either NEMA 5-15 or NEMA 6-15 plug 2.Controls, connections and indications Electronic ballastPower output selector knob Output connectorIEC connector for power cordUSER MANUALA.B.C.D.E.  ENEMA 5-15 NEMA 6-15ACDB3.Product information3.1. Technical specificationsVersion1000W 120V/240V 600W 120V/240V 400W 120V/240V3.8kg/8.82lb 3.8kg/8.82lb 3.8kg/8.82lbProduct weightDimensions (L*W*H)394mmx110mm x73mm   308mmx110mm x73mm   281mmx110mm x73mm  Temperature case 75 ℃ / 167℉Temperature ambient -20 ~ 40 ℃/ -4 ~ 104 ℉Input  voltage +/-10% 120 V  240 V Input current at 100% 8.60 A 4.30 AInput power at 100% 1085 W 1055 W120 V  240 V 5.60 A 2.80 A655 W 645 W120 V  240 V 3.59A 180 A430 W 430WPower factor >0.99Total Harmonic Distortion < 10%Frequency 50 - 60 HzPower inlet IEC C14 Power output settings  50%/75%/100%Ignition voltage: 5 kVInrush current:Plug type:≤37.5 AmpsNema 5-15 Nema 6-15≤50 Amps ≤37.5 AmpsNema 5-15 Nema 6-15≤50 Amps ≤37.5 AmpsNema 5-15 Nema 6-15≤50 AmpsHOT SPOT3.3. HOT SPOTTcase max=60°C/140°F3.4EnvironmentUSER MANUAL394mm(1000W)308mm(600W)281mm(400W)58.5mm110mm73mm3.2. Main DimensionThe product is meant for use in climate rooms. The product may be used in damp environments. The product may not be used in wet environments or outdoors. The 1000 W lamps function optimal when the ambient temperature is between -20 ~ 40℃ / -4 ~ 104 ℉.   7.DisclaimerAny of following circumstances, will not be Efinity’s warranty:1.Install the product without following the wiring diagram in this      manual and cause the product damage.2.Damaged by human reason (like product is soaked in water) or    caused by not following the manual instructions.3.Install or use the product without following the local laws and regula   tions.4.Cover the warrant logo personally, or the client /the third party tries    to maintain, repair, change the product and cause the damage.5.Use of the environment does not meet the provisions of this manual.6.Damaged by force majeure, like abnormal voltage, earthquake,    flood, fire, thunderstroke, transpor tation accidents, etc.7.Man-made damage during carrying, transportation.8.Damaged by unstable match from other company’ (not Efinity’s)    poor design or defective quality products.(like luminaire).9.Beyond the warranty period   6.Warning4.Wiring Diagram-Ballast Case must be GroundedPower surge,power outage,outage overloading may stress or damagethe lamp.As a safety feature,this Soft-Start technology also reduces ballast damage caused by a bulb failure.In case of an unexpected chut-off,please disconnect from the power supply,remove the faultylamp,check for wiring problems,then plug-in the ballast power cord. 5.Protections1.End of Lamp Life(EOL)Protection2.Short circuit protection3.Open circuit protection4.Ignition failure protection5.Thermal protectionUSER MANUALNOTE: This device complies with Part 18 of the FCC Rules.  Changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.  This product may cause interference to radio equipment and should not be installed near maritime safety communications equipment or other critical navigation or communication equipment operating between 0.45–30 MHz. If this occurs, please change outlet or move the lamp far away from other appliance.  (a) The interference potential of device or system:  “Operation is subject to the following two conditions: (1) This device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation.”  (b) Simple measures that can be taken by the user to correct interference:  “NOTE: This equipment generates, uses and can radiate radio frequency energy and, if not installed and used in accordance with the instructions, may cause harmful interference to radio communications. However, there is no guarantee that interfer-ence will not occur in a particular installation. If this equipment does cause harmful interference to radio or television recep-tion, which can be determined by turning the equipment off and on, the user is encouraged to try to correct the interference by one or more of the following measures:  - Reorient or relocate the receiving antenna.  - Increase the separation between the equipment and receiver.  - Connect the equipment into an outlet on a circuit different from that to which the receiver is connected.  - Consult the dealer or an experienced radio/TV technician for help.”Electronic Ballast for  400W/600W/1000W Metal Halide or High Pressure Sodium LampsUSER MANUALUSER MANUAL

Navigation menu