Transtek Medical Electronics AW8001-LS Bluetooth Module with Glass Body Fat Analyzer as host User Manual GBF 1257 B 20130102
Guangdong Transtek Medical Electronics Co.,Ltd Bluetooth Module with Glass Body Fat Analyzer as host GBF 1257 B 20130102
Contents
LS202-b1 manual













![Not applicableTable 4 – Guidance and MANUF ACTURER’S declaration – electromagnetic IMMUNITY – forME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTINGGuidance and manufacturer’s declaration – electromagnetic immunity IMMUN I TY test IEC 60601 TEST LEVE LCompliance levelElectromagnetic environment –guidanceConducted RF IEC 61000-4-6 Radiated RF IEC 61000-4-3 3 Vrms 150 kHz to 80 MHz 3 V/m 80 MHz to 2,5 GHz 3 V/m Recommended separation di stance PV=d ]5,3[1P=d 2.333 800 MHz to 2,5 GHz where P is the m aximum output power rat ing of the transmitter in watts (W) according to the transmitter manufacturer and d is the recommended separation distance in metres (m). Field strengths from fixed RF transmitters, as deter-mined by an electromagnetic site survey,a should be less than the compliance level in each frequency range.bInterference may occur in the vicinity of equipment marked with the following symbol: NOTE 1 At 80 MHz and 800 MHz, the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people.a Field strengths from fixed transm itters, such as base stations for radio (cellular/cordless) telephones and land mobile radios, amateur radio, AM and FM radio broadcast and TV broadcast cannot be predicted theoretically with accuracy. To assess the electromagnetic environment due to fixed RF transmitters, an electromagnetic site survey should be considered. If the measured field strength in the location in which the device is used exceeds the applicable RF compliance level above, the device should be observed to verify normal operation. If abnormal performance is observed, additional measures may be necessary, such as re-orienting or relocating the device.b Over the frequency range 150 kHz to 80 MHz, field strengths should be less than [ V1] V/m. The device is intended for use in the electromagnetic environment specified below. Thecustomer or the user of the device should assure that it is used in such an environment.Portable and mobile RF communications equipment should be used no closer to any part of the device, including cables, than the recommended separation distance calculated from the equation applicable to the frequency of the transmitter.P=d 80 MHz to 800 MHz 1.167 Table 6 – Recommended separation distances between portable and mobile RF communications equipment and the ME EQUIPMENT or ME SYSTEM – forME EQUIPMENT and ME SYSTEMS that are not LIFE-SUPPORTINGRecommended separation distances between portable and mobile RF communications equipment and the device The device is intended for use in an electromagnetic environment in which radiated RF disturbances are controlled. The customer or the user of the device can help prevent electromagnetic interference by maintaining a minimum distance between portable and mobile RF communications equipment (transmitters) and the device as recommended below, according to the maximum output power of the communications equipment.Separation distance according to frequency of transmitter mRated maximum output power of transmitter W150 kHz to 80 MHz PV=d ]5,3[180 MHz to 800 MHz 800 MHz to 2,5 GHz 10,0 1,0 1 01 001For transmitters rated at a maximum output power not listed above, the recommended separation distance d in metres (m) can be estimated using the equation applicable to the frequency of the transmitter, where P is the maximum output power rating of the transmitter in watts (W) according to the transmitter manufacturer. NOTE 1 At 80 MHz and 800 MHz, the separation distance for the higher frequency range applies. NOTE 2 These guidelines may not apply in all situations. Electromagnetic propagation is affected by absorption and reflection from structures, objects and people. 0.2330.1170.7380.3692.3331.1677.3783.69023.3311.67Not applicableNot applicableNot applicableNot applicableNot applicableP=d 2.333P=d 1.167Appendix24 25Appendix](https://usermanual.wiki/Transtek-Medical-Electronics/AW8001-LS.LS202-b1-manual/User-Guide-2473916-Page-14.png)